Bolts in tension (5 cases):
1. |
![]() |
Check with leff patterns according to the table 5.3 (see Effective lengths for base plate T-stubs) |
2. |
![]() |
Check with leff patterns like for column beam for inner bolts no failure mode with prying force Mode 3 |
3. |
![]() |
Check with leff patterns like for column beam, with all cases from the table 5.3. Make an additional check with leff: ![]() From: Wald F., Bouguin V., Sokol Z., Muzeau J.-P. EFFECTIVE LENGTH OF T-STUB OF RHS COLUMN BASE PLATES. Czech Technical University of Prague, University of Blaise Pascal, Clermont Ferrand |
4. |
![]() |
Check with leff patterns according to all cases from the table 5.3 also for an additional inner row. |
5. |
![]() |
Check with leff patterns like for column beam, but without prying force. And check this case: ![]() From: Wald F., Bouguin V., Sokol Z., Muzeau J.-P. EFFECTIVE LENGTH OF T-STUB OF RHS COLUMN BASE PLATES. Czech Technical University of Prague, University of Blaise Pascal, Clermont Ferrand |