Foundation types:
- rectangular
- circular
Parameter |
Unit |
Description |
Material |
- |
Steel material name is using for code check calculation and supported by EN 1993-1-1#Table 3.1 and related national annexes such as NEN-EN 1993-1-1#3.1. Items listed in a Material drop down list depend on chosen code or/and national annex |
Height
|
mm |
Height of the column foundation is used for calculations of NEN6772 (11.7-11.8): |
Grout thickness |
mm |
|
(Ac1/Ac0)½ |
- |
Concrete input coefficient |
For concrete under base plate strength calculations additional data must be provided in the Concrete Input dialog window. Calculations will be performed according to NEN-EN 1992-1-1#6.7 like for partially loaded areas.