Telecommunication check
Telecom design check should comply with the below maximum allowable design value of the vertical rotation angle of a structural node, where antenna structure is braced. The design value of the vertical rotation angle of a node should be calculated with a reference period of one year and be less than following limit values:
|
Maximum allowable vertical rotation angle |
Antenna |
1.0° |
Microwave |
0.7° |
Telecom check is possible in case all of the following conditions are satisfied:
- Technical module No. 176 (Wind load 1D Elements) is enabled;
- Structure is design using the structural steel material;
- Characteristic loads combination(s) are generated or/and defined manual way;
- Results are calculated.
Telecom design check is only performed on the structural nodes, where antenna structure(s) is braced. Such a braced structures is seen as the nodal concentrated loads defined or/and generated in the load definition part.