Longitudinal reinforcement input format

Longitudinal reinforcement can be provided in such format:

  • For beams 2R20 – two bars with diameter 20 mm;
  • For plates R10-250 – bar with diameter 10mm each 250mm.

 

As reinforcement of beams bar bundles can be used.

Maximum 3 same diameter bars can be in one bundle. Bundle from 3 bars can be only triangle configuration. Bundle from two bars can be horizontal or vertical. For vertical bundle last label letter must be "V".

Longitudinal reinforcement input format

 

1RRR16

 

Longitudinal reinforcement input format

 

1RR16

 

Longitudinal reinforcement input format

 

1RR16V

 

Longitudinal reinforcement input format

 

top

 

bottom

2R20+2RR16V+1RR16

 

2R20+2RR16V+1RRR16

Longitudinal reinforcement input format

 

top

 

bottom

2R20+1RR16

 

2R20+1RRR16

Longitudinal reinforcement input format

 

top

 

bottom

2RR20V+1RR20

 

2RR20V+1RRR16

Longitudinal reinforcement input format

 

top

 

bottom

2RR20V+1RR20

 

2RR16+1RRR20