Partial factors for a material property used in reinforced concrete calculations:
Code |
Persistent & transient |
Fire design |
||
Reinforcement |
Concrete |
Reinforcement |
Concrete |
|
NEN |
1.15 |
1.2 |
1.0 |
1.2 |
NEN-EN |
1.15 |
1.5 |
1.0 |
1.0 |
EN |
1.15 |
1.5 |
1.0 |
1.0 |
The values for partial factors are taken from table Box values.
It is possible to define user values as a commercial extension option; for example in case of prefab fabrication, where each factory may use different partial factors. In options Concrete code the defined subcode can be selected.