Check wmax |
Check (w2 + w3) |
|||||
|
Structure part |
Check type |
Comb. for w1 |
Comb. for w2 |
Comb. for w3 |
Limit deformation |
Comb. for w2 |
Comb. for w3 |
Limit deformation |
|
Roof & Roof cantilever |
None |
Ch.C(w1) |
Qu.C. |
Ch.C |
None |
Qu.C. |
Ch.C |
None |
|
User |
User input |
User input |
||||||
|
General |
1/250 |
1/250 |
||||||
|
Roofs + Persons |
Ch.C(w1) |
1/250 |
Fr.C |
1/333 |
||||
|
Floor & Floor cantilever |
None |
Fr.C(w1) |
Qu.C |
None |
Fr.C |
None |
||
|
User |
User input |
User input |
||||||
|
General |
1/250 |
1/333 |
||||||
|
With cracking sensitive walls |
1/250 |
1/500 |
||||||
|
|
|
Check u (on total height of the building) |
Check ui (on the height of the each storey) |
|||||
|
Structure part |
Check type |
|
Comb. for u_creep |
Comb. for u* |
Limit deformation |
Comb. for u_creep |
Comb. for ui* |
Limit deformation |
|
Column |
1 level |
|
Qu.C |
Ch.C |
L/300 |
Qu.C |
Ch.C |
L/300 |
|
1 storey, industrial buildings |
L/150 |
L/150 |
||||||
|
Multistorey |
|
L/500 |
L/300 |
|||||
|
User/h |
|
|
|
|||||
|
User/l |
|
|
|
|||||
|
None |
|
|
|
|||||