Insulation materials (NEN)

Insulation materials according to the NEN 6069/6072:

Sprayed:

  • Cafcote 280

Material

Cafcote 280

Available thickness

20-65 mm

Manufacturer

NVM Products B.V.
W. Fenengastraat 25-27
1096 BL Amsterdam
The Netherlands

Tel: +31 (0)20 - 640 1050
Fax: +31 (0)20 - 640 6824
Email: info@nvmproducts.nl

 

  • Mandolite CP2

Material

Mandolite CP2

Available thickness

5-40 mm

Manufacturer

Reppel B.V.
Pieter Zeemanweg 107
3316 GZ Dordrecht
The Netherlands

Tel.: +31 (0)78 6174400
Fax: +31 (0)78 6171006
E-mail: reppel@reppel.nl

 

The steel beams (part of the main armature) under the story floors /roof floors on the levels (in the rooms) according to the section fire resistant with Mandolite CP2, a fiber free modified cement bound Vermiculite spray plaster. Realization work not in sight. Requiring fire resistant minutes according to the NEN 6069. Calculations of the isolation thickness carried out by the supplier Reppel B.V. Dordrecht. This for approval of the management. b. The nodes of the beams and columns and the column parts connected to the fire resistant plates, also covered by fire resistant Mandolite CP2. c. Prior to the fire resistant sprayings, the application company should be guaranteed that the steel has been blasted in a correct way (SA - 21/2) and is provided with a proper corrosion resistant painting system. The corrosion resistant painting system should be checked on attachment and cement durability (Ph 12-121/2). d. The procession of Mandolite CP2 should meet the requirements and expertise of a specialized and qualified application company appointed by Reppel B.V. Dordrecht. e. All building parts with in sight should be protected properly for "overspray".

 

Plate:

  • Fiproplaat

Material

Fiproplaat

Available thickness

16-32 mm

Manufacturer

Preficon Europe B.V.
Havenweg 20C
5145 NJ Waalwijk
The Netherlands

Tel.: +31 (0)416 69 71 71
Email: info@preficon.com

 

  • Promapyr-350

Material

Promapyr-350

Available thickness

15-33 mm

Manufacturer

Promat B.V.
Vleugelboot 22, 3991 CL Houten
Postbus 475, 3990 GG Houten
The Netherlands

Tel.: +31 (0)30 241 07 70
Fax: +31 (0)30 241 07 71
Email: info@promat.nl

 

  • Promatect-H

Material

Promatect-H

Available thickness

12-25 mm

Manufacturer

Promat B.V.
Vleugelboot 22, 3991 CL Houten
Postbus 475, 3990 GG Houten
The Netherlands

Tel.: +31 (0)30 241 07 70
Fax: +31 (0)30 241 07 71
Email: info@promat.nl

 

  • Pumica

Material

Pumica

Available thickness

12-45 mm

Manufacturer

PULL RHENEN BV
Utrechtsestraatweg 222
NL-3911 TX Rhenen
The Netherlands

Tel.: 0031 318471001
Fax : 0031 318-472088
E-mail: info@pullrhenen.nl

 

  • Rinoflam-S (column)

Material

Rinoflam-S

Available thickness

12.5-30 mm

Manufacturer

Saint-Gobain Gyproc Nederland
Postbus 73
4130 EB Vianen
The Netherlands

Tel: 0347-325100
Fax: 0347-325125
E-mail: info@gyproc.nl

 

  • Rinoflam-S (beam)

Material

Rinoflam-S

Available thickness

12.5-30 mm

Manufacturer

Saint-Gobain Gyproc Nederland
Postbus 73
4130 EB Vianen
The Netherlands

Tel: 0347-325100
Fax: 0347-325125
E-mail: info@gyproc.nl

 

  • Supalux-S

Material

Supalux-S

Available thickness

6-20 mm

Manufacturer

Promat B.V.
Vleugelboot 22, 3991 CL Houten
Postbus 475, 3990 GG Houten
The Netherlands

Tel.: +31 (0)30 241 07 70
Fax: +31 (0)30 241 07 71
Email: info@promat.nl

 

  • Supalux-V

Material

Supalux-V

Available thickness

20-40 mm

Manufacturer

Promat B.V.
Vleugelboot 22, 3991 CL Houten
Postbus 475, 3990 GG Houten
The Netherlands

Tel.: +31 (0)30 241 07 70
Fax: +31 (0)30 241 07 71
Email: info@promat.nl

 

  • Promatect-L

Material

Promatect-L

Available thickness

15-50 mm

Manufacturer

Promat B.V.
Vleugelboot 22, 3991 CL Houten
Postbus 475, 3990 GG Houten
The Netherlands

Tel.: +31 (0)30 241 07 70
Fax: +31 (0)30 241 07 71
Email: info@promat.nl

 

  • Conlit Verlijmd

Material

Conlit Verlijmd

Available thickness

20-90 mm

Manufacturer

ROCKWOOL B.V.
Industrieweg 15
6045 JG Roermond 
The Netherlands

Tel.: 0475 35 35 35
Fax.: 0475 35 36 66

 

  • Conlit Dry-Fix

Material

Conlit Dry-Fix

Available thickness

20-90 mm

Manufacturer

ROCKWOOL B.V.
Industrieweg 15
6045 JG Roermond 
The Netherlands

Tel.: 0475 35 35 35
Fax.: 0475 35 36 66

 

 

Foaming:

  • Promapaint-SC

Material

Promapaint-SC

Available thickness

0.4-2.4 mm

Manufacturer

Promat B.V.
Vleugelboot 22, 3991 CL Houten
Postbus 475, 3990 GG Houten
The Netherlands

Tel.: +31 (0)30 241 07 70
Fax: +31 (0)30 241 07 71
Email: info@promat.nl

 

  • Flame Guard HCA-WL

Material

Flame Guard HCA-WL

Available thickness

0.5-5.7 mm

Description specifications

Foaming paint water-based

Manufacturer

Flame Guard B.V.
Postbus 6572
6503 GB NIJMEGEN
Hulzenseweg 10-20
6534 AN NIJMEGEN

Tel.: +31 (0)24-3789581
Fax : +31 (0)24-3787583

 

Before you apply HCA-WL you first need to apply a primer coating, preferable a HCA primer. Other primers based on epoxy- or sink phosphate can be used as well. Damages in an existing primer coating need to be repaired before applying HCA-WL. When applying a coating on thermal sink steel you should use an appropriate wash-primer. When applying on old paint coating please contact Flame Guard. A blasted subsoil is ideal for applying a HCA primer. Dependent on the smoothness of the surface a coating of 50 - 100 g/m2 needs to be applied on the steel, preferable in a cross coating. Take account of a drying time of 24 hours, before applying the HCA-WL. Using HCA-WL: We recommend to carry out the application with airless equipment and to apply 2 or 3 coatings of HCA-WL. Applying with brush or paint roller is an option, however it takes several labour courses. It is possible to apply the top coating HCA WL with a HCA Topcoat, for a better effect of the paint cover, or for the finishing touch apply a coloured version. Take account of a drying time of 8 hours in between the coatings, at a temperature of 21 C and 65 % RL (one night). If desired apply a top coating HAC Topcoat on the HCA WL. Finishing with HCA Topcoat: HAC Topcoat serves as extra protection of HCA WL at a high atmospheric humidity, it protects against extra pollution of dust and it obtains an increased finishing degree. HAC Topcoat kann be applied with an airless spray, brush or paint roller, and a quantity of 100-200 g/m2 HCA Topcoat can be applied in one single coating, after a drying time of about 2 days for HCA WL. HCA Topcoat is available in every RAL colour.

 

  • Multifire System S605

Material

Multifire System S605

Available thickness

0.2-3.4 mm

Manufacturer

Multifire International B.V.
Willem Fenengastraat 25
1096 BL AMSTERDAM
The Netherlands

Tel.: +31 (0)20-345 9020
Fax : +31 (0)20-345 9021
E-mail: info@multifire.nl

 

  • Multifire System S605WB

Material

Multifire System S605WB

Available thickness

0.2-2 mm

Manufacturer

Multifire International B.V.
Willem Fenengastraat 25
1096 BL AMSTERDAM
The Netherlands

Tel.: +31 (0)20-345 9020
Fax : +31 (0)20-345 9021
E-mail: info@multifire.nl

 

  • Pyrotech-SP

Material

Pyrotech-SP

Available thickness

0.275-5.46 mm

 

  • Unitherm

Material

Unitherm

Available thickness

0.4-2.5 mm

 

Implemented database with Lambda values for isolation is not valid anymore in relation to the EN1993-1-2, because art. 3.4.3 is referring to a new EN-code for determination of Lambda values based on the other technology and probably small differences for Lambda values for most types. RHS- & CHS-sections in combination with foam or sprayed isolation can give big differences in fire resistance calculation. At this moment no Lambda values according to the related EN-code are available. The current database is used as "Indicative", with warning that calculated thickness is too small for RHS- & CHS-sections in combination with foam or sprayed isolation. For proper results contact the supplier of the isolation material and apply the proper lambda value using "User" insulation material

 

The thermal conduction coefficient of the isolation material is expressed in Watt/mK. It is an effective value derived from fire tests and can be applied for a practical temperature course. In this situation it is effective because we choose for a global calculation method.

 

Effective thermal conduction coefficients of many applied isolation materials:

 

Fire resistant paints

0.005-0.02 W/mK

Sprayed mineral fibres (rock wool)

0.10

Perlite or vermiculite plates

0.15

Asbestos-silicate plates

0.15

Asbestos-free silicate plates

0.15

Plasterboards

0.20

Mineral fibre boards (rock wool)

0.25

Aerated concrete

0.30

Aerated concrete

0.45

Aerated concrete

0.65

Lightweight concrete

0.80

Brickwork from brick/sand-lime brick

1.20

Gravel concrete (amorphous extra material)

1.30

Gravel concrete (crystal extra material)

1.70

 

The section factor is determined by the geometry of the cross section and in which way it is exposed to the fire. In this program we distinguish three- and four sided kinds of heating, see NEN 6072 art. 10.2.1.2 and also the book Spanned Steel, Constructing A, Chapter 5. In addition integrated beams are calculated. BRAWESTA calculates the steel temperature of these beams based on the section factor of the under flange, see also 5.6 of Constructing A. For the ordinary sections the program provides a calculation of the section factor. For special cases the section factor can be entered separately, Select "Different calculation method ". For example the tube sections. These sections are NOT registered in the section file. The section factor of (not thick walled) tubes is: 1/d [m-1].