For the input of database cross sections are used parameters measured in meters [m]. For the designation of database cross sections are used values in millimeters [mm].

 

Dimensions [m]

Designation [mm]

Japanese H-sections (HJ):

 

UC cross section

HJ hnom x bnom x tw x tf

for tapered section: HJ hnom x bnom x tw x tf (hB - hE)

for castellated section: HJ hnom x bnom x tw x tf / ht

 

where:

HJ - symbol of database Japanese H-sections

hnom - nominal height [mm]

bnom - nominal width [mm]

tw - web thickness [mm]

tf - flange thickness [mm]

hB - begin height of tapered section [mm]

hE - end height of tapered section [mm]

Castellated HJ section

 

ht - height of castellated section [mm]

 

Dimensions: JIS G 3192: 2005; JIS A 5526: 2005