Codecheck: NEN-EN (except Timber)

 

 

Check wmax

Check (w2 + w3)

Structure part

Check type

Comb. for w1

Comb. for w2

Comb. for w3

Limit deformation

Comb. for w2

Comb. for w3

Limit deformation

Roof &

Roof cantilever

None

Ch.C(w1)

Qu.C.

Ch.C

None

Qu.C.

Ch.C

None

User

User input

User input

General

1/250

1/250

Roofs + Persons

Ch.C(w1)

1/250

Fr.C

1/333

Floor &

Floor cantilever

None

Fr.C(w1)

Qu.C

None

Fr.C

None

User

User input

User input

General

1/250

1/333

With cracking

sensitive walls

1/250

1/500

 

 

Check u (on total height of the building)

Check ui (on the height of the each storey)

Structure part

Check type

 

Comb. for u_creep

Comb. for u*

Limit deformation

Comb. for u_creep

Comb. for ui*

Limit deformation

Column

1 level

 

Qu.C

Ch.C

L/300

Qu.C

Ch.C

L/300

1 storey,

industrial buildings

L/150

L/150

Multistorey

 

L/500

L/300

User/h

 

 

 

User/l

 

 

 

None