Codecheck: NBN-EN

 

 

Check wmax

Check (w2 + w3)

Structure part

Check type

Comb.

for w1

Comb. for w2

Comb. for w3

Limit deformation

Comb. for w2

Comb. for w3

Limit deformation

Roof &

Roof cantilever

None

Fr.C(w1)

Qu.C.

Fr.C

None

Qu.C.

Ch.C

None

User

User input

User input

General

(for structure part

Roof cantilever only)

1/300

1/250

Roof stiff

(for structure part Roof only)

Roofs  flexible

(for structure part Roof only)

Ceiling

 &

 Ceiling cantilever

None

None

None

User

User input

User input

Ceiling coating

1/300

1/350

Ceiling flexible

1/250

 

 

Check u (on total height of the building)

Check ui (on the height of the each storey)

Structure part

Check type

 

Comb. for w2

Comb. for

w2 + w3

Limit deformation

Comb. for w2

Comb. for

w2 + w3

Limit deformation

Column

Vertical element

 

Qu.C.

Ch.C.

1/500

Qu.C.

Fr.C.

1/250

User/h

 

User input

User input

User/l

 

User input

User input

None

 

None

None